PSA

A national Public Service Announcement (PSA)premiered yesterday  urging motorists to “slow down and move over

Please take a moment and watch it.


Training - WFD

Firefighter I & II will begin September 7th.  This class is open to all outside departments, also.

The class is sponsored by WVFD and is being taught by Fire Training Innovations, LLC.

SIGN UP NOW!


News Headlines

Thu. Sep 2nd 2010
Carnival 2010 opens tonight at 6pm

Tonight is the night!!!!
The 3 day Fireman's Carnival opens to night at Hollow Park at 6pm.  Rainbow Amusements is p...

Read more »


Sun. Aug 29th 2010
And what a wet day it became.................

The sun was out.  The day was warm.  There was not a rain cloud in the sky - but boy, oh boy, did it rain at the Wo...

Read more »


Tue. Aug 24th 2010
Busy 2 weeks coming up for WVFD

It's that time of year ........... school starting, back to school supply shopping and all the anticipation of another holida...

Read more »

Apparatus Gallery
Contact Information

The Association of the Woodbury Volunteer Fire Department
25 Quassuk Road
Woodbury, CT  06798

Non-Emergency:
203-263-3100

Emergency:
911

Contact Us
Driving Directions
Map

Member Login

Username:


Password:




Links

Pleural Mesothelioma Center

Pleural mesothelioma is the most common form of mesothelioma. Among other issues, fluid buildup in the chest cavity can cause...


Town of Woodbury

This link will bring you to the Town of Woodbury's website where you can view other departments within the town.


Fire Rescue 1

This is one of the fastest growing firefighter related websites out there. The information is current and very informative -...




 News
 Print this page
 Subscribe to this RSS feed

Firefighter Face Protection: Goggles vs. Faceshields
Fri. Jan 29th 2010

One of the proposals for the next edition of NFPA 1971 is to make goggles mandatory and faceshields optional

 

Editor's note: Jeffrey and Grace Stull's latest article outlines how changes are being advocated for firefighter eye and face protection in the current revision effort for NFPA 1971. Share your thoughts, experiences and preferences in the member comments section below.

 

By Jeffrey O. and Grace G. Stull

There is a continuing debate about the type of eye and face protection that should be provided to firefighters. Some groups advocate that traditional faceshields offer the best approach for the fire service while others insist that goggles must be mandated. This argument has existed over decades and practices within each department often align themselves with one approach or the other. The debate is coming to a head because the National Fire Protection Association technical committee responsible for the standard on structural firefighting protective clothing and equipment is in the process of undertaking its next revision and this matter has been a perennial issue with new directions now being sought.

Design and performance requirements for firefighters' helmets were first developed in 1977 by what was then the National Fire Prevention and Control Administration as part of the U.S. Department of Commerce (formerly under the National Bureau of Standards). This report set the first criteria for firefighter helmets that were adopted by the NFPA in 1979 (the standard was designated NFPA 1972), but only addressed head protection.

It was not until the 1987 edition of NFPA 1972 that any type of eye or face protection was adopted. In that edition, faceshields became a mandatory part of the helmet and specific design and performance criteria were established. Initial performance was limited to flame, heat and impact resistance. In 1992, scratch resistance and light transmission requirements were added. In the 1997 edition, helmet specifications were combined with garments, glove and footwear as part of the new ensemble-based standard that replaced NFPA 1971.

Fields of vision
Goggles were added to the ensemble standard in 2000. In that edition, NFPA 1971 required either a faceshield, or goggles, or both to be provided as part of the helmet. Both faceshields and goggles had to be attached and provided as part of the helmet. All of the criteria that were applied to faceshields were also applied to goggles. However, instead of defining the specific dimensions for the faceshield, the standard required that faceshields or goggles provide a certain field of vision based on angular directions from the eyes. In the 2007 edition, NFPA 1971 no longer required that the goggles be attached to the helmet.

In the current revision effort, changes are being advocated for eye and face protection. Part of this effort is driven by the fact that there has been an inconsistency for NFPA 1971 with NFPA 1500, Standard on Fire Department Occupational Safety and Health Program. NFPA 1500 requires firefighters to have eye and face protection during operations where eye and face hazards are present.

It specifically requires "primary eye protection shall meet the requirements of ANSI Z87.1, Practice for Occupational and Educational Eye and Face Protection." (ANSI Z87.1 specifies requirements for different types of industrial eye and face protective devices including safety glasses, goggles, and faceshields, but does not include heat and flame requirements). The ANSI standard also states that the helmet faceshields should not be considered primary eye protection but wearing of an SCBA does constitute primary eye and face protection.

New proposals
One of the proposals for the next edition of NFPA 1971 is to make goggles mandatory and faceshields optional. In this approach, all helmets would have to be supplied with goggles and may or may not include a faceshield. This is a departure from the current requirements, where the helmet must have either a faceshield or a set of goggles (or both). It would mean that all helmets ordered would include goggles, whether requested or not. One of the side issues is whether the goggles would simply be provided with the helmet or be required to be attached to the helmet. Some believe that the attachment of goggles to the helmet is the only way to ensure that they will be worn even though end users may still opt for using faceshields.

There has been some discussion that the time has come for the fire service to recognize eye and face protection separately from the helmet. Proponents of this approach state that it is important to design eye and facewear to meet the intended hazards and set performance requirements accordingly. 

Others contend that departments would rather make this choice and that attachment of goggles to the helmet only accelerates their degradation and renders the goggles unusable if left unprotected on top of the helmet. This proposal has obviously stirred a considerable amount of debate. Many major fire departments do not have goggles on their helmets and provide goggles separately. Several firefighters carry their goggles in the coat pocket to keep them clean and protected until needed.

It has been further proposed that a heat and flame resistant cover be provided for goggles when mounted on top of the helmet. Some departments claim that these devices are effective and are able to maintain the goggles in a good condition during working fires and other emergency operations. Other departments don't want anything else on their helmets or prefer only the faceshield to be attached because of their operational practices.

Some departments prefer faceshields. These faceshields may be of the conventional type which rest on top of the brim and then move down in front of the eye and upper part of the face. Like goggles, firefighters complain that the faceshield quickly becomes opaque and distorted in the first "good" fire exposure requiring its replacement. Alternatively, there are faceshields that are mounted underneath the brim and flip down in front of the eyes when needed. Firefighters often use faceshields of one type of other to help protect the SCBA facepiece, which serves as the firefighter's primary eye protection.

Different protection
Regardless of the type used, faceshields are not primary eye protection because particulates can easily come up from the bottom or sides directly into the eyes. One other type of faceshield that has been available for several years is of a design where it slides in and out of the shell, much like some motorcycle helmets, but these helmets do not have a "traditional" fire service appearance.

There is further a move to incorporate requirements from the ANSI Z87.1 standard for both goggles and eyewear. As described above, this standard addresses industrial eye and face protection, but has several criteria related to the optical quality and other features of eye and facewear that are not addressed in the NFPA 1971 standard. The implementation of these requirements is seen as a positive improvement, but the committee has to study which requirements to cite and ensure that their specification does not cause conflicts with other criteria in the standard.

Lastly, there has been some discussion that the time has come for the fire service to recognize eye and face protection separately from the helmet. Proponents of this approach state that it is important to design eye and facewear to meet the intended hazards and set performance requirements accordingly. It is argued that this approach offers the greatest flexibility since new criteria are provided that define appropriate eye protection for firefighters and manufacturers can decide to either separately sell these product or integrate the devices with helmets. Regardless, the approach then becomes one of continuing flexibility for fire departments to choose how they protect their members from eye and face hazards. If selected, this approach would require that NFPA 1500 reference use of eye and face protection devices that meet NFPA 1971.

The experience, sentiments, and opinions of the fire service needs to be heard on the issue of goggles versus helmets. We have found a variety of practices for eye and face protection throughout the country with passionate stances for each respective approach. NFPA 1500 makes it clear that both eye and face protection are needed during emergencies.

When the SCBA facepiece is not being worn and emergency operations are being conducted, eye and face protection must be worn when specific exposure hazards are present. How fire departments meet these requirements and how industry responds with different product options remains a matter of how the next edition of NFPA 1971 addresses the subject on goggles and faceshields.

 

About the author


Sponsored by Globe

Jeffrey O. and Grace G. Stull are president and vice president respectively of International Personnel Protection, Inc., which provides expertise on the design, evaluation, selection and use of personnel protective clothing, equipment and related products to end users and manufacturers. They are considered amongst the leading experts in the field of personal protective equipment. Send questions or feedback to Jeff or Grace atJeffrey.O.Stull@FireRescue1.com.




View all News Postings



A simple "Click"

A simple "click" can save you life!

http://www.youtube.com/watch?v=6kYqjTA_VEg&feature=fvw

and

http://www.youtube.com/watch?v=e6Qhmdk4VNs&feature=related

Remember 

 No Belt - Gets you 30 days off

There are no second chances!


FOREST FIRE DANGER

Smokey Bear

Daily Forest Fire Danger Report

The Forest Fire Danger Level 

Friday, September 3, 2010

Moderate

Open Burning Permits are not being issued today due to overcast conditions

 To view the requirements of an Open Burning Permit.  Additional info also available at www.woodburyfm.org


Monthly Driver Day

This month's dirver training day is:

Saturday, August 21  from 8 am to 8pm

Each block is 1 1/2 hours per person.

Please sign up early.

Annual eval's take priority

For more info: contact Lt. Garms

Check the calendar to view open slots


Over the Air

WVFD is now on air during Fire Calls

Listen in and hear whats going on

http://www.radioreference.com/apps/audio/?feedId=2978


Request ~ Please

Please don't forget to sign our guest book. 

We would like to know what you think of our site. 

We gladly take all suggestions.


Twitter

Twitter ....

http://twitter.com/Woodburyfdorg


Recent Calls

Mon. Aug 23rd 2010
Busy weekend for False Alarm Activations

Friday night started the weekend off for multiple calls for commercial fire alarm activations.
49 Jacks Bridge Road start...

Read more »


Mon. Aug 9th 2010
Single weekend call

The WVFD remained quiet for the most part this weekend.  Saturday morning a little after 9 am they did respond to a comm...

Read more »


Thu. Aug 5th 2010
Early Morning Mutual Aid

WVFD responded to a request from the Roxbury Volunteer Fire Department early this morning.  They were at a working struc...

Read more »

Upcoming Events

Mon. Sep 6th 2010 6:00pm
OIC - Car 1


Tue. Sep 7th 2010 6:00pm
OIC - Car 8


Tue. Sep 7th 2010 6:30pm
Fire Fighter 1 / 2


Every 2nd Wed. 8:00pm
Department Meeting


Every 1st Thu. 8:00pm
Company Meetings


Every 1st Thu. 7:00pm
Company Training


Last Mon. of the month 7:30pm
Officer's Meeting


Every 3rd Thu. 7:30pm
Board of Fire Commissioners


Every Sun. 6:00pm
OIC ~ CAR 3


Every 3rd Thu. 6:00pm
Orenuag Company ~ Truck Checks


Every Fri. 6:00pm
OIC ~ CAR 4


Every Sat. 6:00pm
OIC ~ CAR 1


Every Mon. 6:00pm
OIC ~ Car 2


Every Tue. 6:00pm
OIC ~ Car 8

Picture Gallery
Search Our Site

Search:



2010 Call Volume
January  25
February  23
March  20
April  21
May  28
June  20
July  22
August  
September  
October  
November  
December  
Total 159

View Call Volume History

Visitor Poll

Do you like our Website?



Birthdays for September

15th Daniel deGraffenreid
17th Chris Swendsen
25th Glen Dains


YourFirstDue.com Managed web hosting for Fire/EMS



Login



Copyright © 2006-2010. YourFirstDue Inc.. All Rights Reserved. Designated trademarks and brands are the property of their respective owners. Content on this web site is supplied by The Association of the Woodbury Volunteer Fire Department. YourFirstDue Inc. cannot be held responsible or liable for any content, text, pictures, or any other media found on this web site. Maintained by the members and staff of The Association of the Woodbury Volunteer Fire Department.

This site has been
viewed 183,418 times.